PLoS One ; 19(5): e0301041, 2024.
Article En | MEDLINE | ID: mdl-38701088

OBJECTIVE: To evaluate the safety and performance of an implantable near-infrared (NIR) spectroscopy sensor for multi-metabolite monitoring of glucose, ketones, lactate, and ethanol. RESEARCH DESIGN AND METHODS: This is an early feasibility study (GLOW, NCT04782934) including 7 participants (4 with type 1 diabetes (T1D), 3 healthy volunteers) in whom the YANG NIR spectroscopy sensor (Indigo) was implanted for 28 days. Metabolic challenges were used to vary glucose levels (40-400 mg/dL, 2.2-22.2 mmol/L) and/or induce increases in ketones (ketone drink, up to 3.5 mM), lactate (exercise bike, up to 13 mM) and ethanol (4-8 alcoholic beverages, 40-80g). NIR spectra for glucose, ketones, lactate, and ethanol levels analyzed with partial least squares regression were compared with blood values for glucose (Biosen EKF), ketones and lactate (GlucoMen LX Plus), and breath ethanol levels (ACE II Breathalyzer). The effect of potential confounders on glucose measurements (paracetamol, aspartame, acetylsalicylic acid, ibuprofen, sorbitol, caffeine, fructose, vitamin C) was investigated in T1D participants. RESULTS: The implanted YANG sensor was safe and well tolerated and did not cause any infectious or wound healing complications. Six out 7 sensors remained fully operational over the entire study period. Glucose measurements were sufficiently accurate (overall mean absolute (relative) difference MARD of 7.4%, MAD 8.8 mg/dl) without significant impact of confounders. MAD values were 0.12 mM for ketones, 0.16 mM for lactate, and 0.18 mM for ethanol. CONCLUSIONS: The first implantable multi-biomarker sensor was shown to be well tolerated and produce accurate measurements of glucose, ketones, lactate, and ethanol. TRIAL REGISTRATION: Clinical trial identifier: NCT04782934.


Ethanol , Feasibility Studies , Ketones , Lactic Acid , Spectroscopy, Near-Infrared , Humans , Ketones/analysis , Male , Ethanol/analysis , Spectroscopy, Near-Infrared/methods , Adult , Female , Lactic Acid/analysis , Lactic Acid/blood , Blood Glucose/analysis , Middle Aged , Diabetes Mellitus, Type 1/blood , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Glucose/analysis
3.
Anal Chim Acta ; 1306: 342613, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38692794

Glucose detection is of significant importance in providing information to the human health management. However, conventional enzymatic glucose sensors suffer from a limited long-term stability due to the losing activity of the enzymes. In this work, the AuNi bimetallic aerogel with a well-defined nanowire network is synthesized and applied as the sensing nanomaterial in the non-enzymatic glucose detection. The three-dimensional (3D) hierarchical porous structure of the AuNi bimetallic aerogel ensures the high sensitivity of the sensor (40.34 µA mM-1 cm-2). Theoretical investigation unveiled the mechanism of the boosting electrocatalytic activity of the AuNi bimetallic aerogel toward glucose. A better adhesion between the sensing nanomaterial and the screen-printing electrodes (SPEs) is obtained after the introduction of Ni. On the basis of a wide linearity in the range of 0.1-5 mM, an excellent selectivity, an outstanding long-term stability (90 days) as well as the help of the signal processing circuit and an M5stack development board, the as-prepared glucose sensor successfully realizes remote monitoring of the glucose concentration. We speculate that this work is favorable to motivating the technological innovations of the non-enzymatic glucose sensors and intelligent sensing devices.


Biosensing Techniques , Electrochemical Techniques , Gels , Glucose , Gold , Nickel , Biosensing Techniques/methods , Nickel/chemistry , Gels/chemistry , Gold/chemistry , Glucose/analysis , Electrodes , Nanowires/chemistry , Humans , Limit of Detection
4.
Biosensors (Basel) ; 14(4)2024 Mar 28.
Article En | MEDLINE | ID: mdl-38667154

We designed and optimized a glucose biosensor system based on a screen-printed electrode modified with the NAD-GDH enzyme. To enhance the electroactive surface area and improve the electron transfer efficiency, we introduced graphene oxide (GO) and ferrocene-modified linear poly(ethylenimine) (LPEI-Fc) onto the biosensor surface. This strategic modification exploits the electrostatic interaction between graphene oxide, which possesses a negative charge, and LPEI-Fc, which is positively charged. This interaction results in increased catalytic current during glucose oxidation and helps improve the overall glucose detection sensitivity by amperometry. We integrated the developed glucose sensor into a flow injection (FI) system. This integration facilitates a swift and reproducible detection of glucose, and it also mitigates the risk of contamination during the analyses. The incorporation of an FI system improves the efficiency of the biosensor, ensuring precise and reliable results in a short time. The proposed sensor was operated at a constant applied potential of 0.35 V. After optimizing the system, a linear calibration curve was obtained for the concentration range of 1.0-40 mM (R2 = 0.986). The FI system was successfully applied to determine the glucose content of a commercial sports drink.


Biosensing Techniques , Ferrous Compounds , Glucose , Graphite , Metallocenes , Polyethyleneimine , Graphite/chemistry , Metallocenes/chemistry , Ferrous Compounds/chemistry , Polyethyleneimine/chemistry , Glucose/analysis , Electrodes , Oxidation-Reduction
5.
Biosensors (Basel) ; 14(4)2024 Apr 03.
Article En | MEDLINE | ID: mdl-38667165

The exploration into nanomaterial-based nonenzymatic biosensors with superb performance in terms of good sensitivity and anti-interference ability in disease marker monitoring has always attained undoubted priority in sensing systems. In this work, we report the design and synthesis of a highly active nanocatalyst, i.e., palladium and platinum nanoparticles (Pt&Pd-NPs) decorated ultrathin nanoporous gold (NPG) film, which is modified on a homemade graphene paper (GP) to develop a high-performance freestanding and flexible nanohybrid electrode. Owing to the structural characteristics the robust GP electrode substrate, and high electrochemically catalytic activities and durability of the permeable NPG support and ultrafine and high-density Pt&Pd-NPs on it, the resultant Pt&Pd-NPs-NPG/GP electrode exhibits excellent sensing performance of low detection limitation, high sensitivity and anti-interference capability, good reproducibility and long-term stability for the detection of small molecular biomarkers hydrogen peroxide (H2O2) and glucose (Glu), and has been applied to the monitoring of H2O2 in different types of live cells and Glu in body fluids such as urine and fingertip blood, which is of great significance for the clinical diagnosis and prognosis in point-of-care testing.


Biomarkers , Biosensing Techniques , Electrochemical Techniques , Gold , Graphite , Metal Nanoparticles , Palladium , Platinum , Graphite/chemistry , Gold/chemistry , Platinum/chemistry , Palladium/chemistry , Metal Nanoparticles/chemistry , Biomarkers/urine , Humans , Hydrogen Peroxide , Alloys/chemistry , Glucose/analysis , Electrodes , Paper
6.
Lab Chip ; 24(9): 2454-2467, 2024 Apr 30.
Article En | MEDLINE | ID: mdl-38644805

Safe, accurate, and reliable analysis of urinary biomarkers is clinically important for early detection and monitoring of the progression of chronic kidney disease (CKD), as it has become one of the world's most prevalent non-communicable diseases. However, current technologies for measuring urinary biomarkers are either time-consuming and limited to well-equipped hospitals or lack the necessary sensitivity for quantitative analysis and post a health risk to frontline practitioners. Here we report a robust paper-based dual functional biosensor, which is integrated with the clinical urine sampling vial, for the simultaneous and quantitative analysis of pH and glucose in urine. The pH sensor was fabricated by electrochemically depositing IrOx onto a paper substrate using optimised parameters, which enabled an ultrahigh sensitivity of 71.58 mV pH-1. Glucose oxidase (GOx) was used in combination with an electrochemically deposited Prussian blue layer for the detection of glucose, and its performance was enhanced by gold nanoparticles (AuNPs), chitosan, and graphite composites, achieving a sensitivity of 1.5 µA mM-1. This dual function biosensor was validated using clinical urine samples, where a correlation coefficient of 0.96 for pH and 0.98 for glucose detection was achieved with commercial methods as references. More importantly, the urine sampling vial was kept sealed throughout the sample-to-result process, which minimised the health risk to frontline practitioners and simplified the diagnostic procedures. This diagnostic platform, therefore, holds high promise as a rapid, accurate, safe, and user-friendly point-of-care (POC) technology for the analysis of urinary biomarkers in frontline clinical settings.


Biosensing Techniques , Paper , Point-of-Care Systems , Humans , Hydrogen-Ion Concentration , Gold/chemistry , Glucose/analysis , Urinalysis/instrumentation , Glucose Oxidase/chemistry , Glucose Oxidase/metabolism , Electrochemical Techniques , Metal Nanoparticles/chemistry , Graphite/chemistry , Biomarkers/urine
7.
Biosens Bioelectron ; 257: 116310, 2024 Aug 01.
Article En | MEDLINE | ID: mdl-38643549

Nanozymes have been widely used in the field of biosensing owing to their high stability, low cost, adjustable catalytic activity, and convenient modification. However, achieving high selectivity and sensitivity simultaneously in nanozyme-based colorimetric sensing remains a major challenge. Nanozymes are nanomaterials with enzyme-simulating activity that are often used as solid-phase adsorbents for sample pretreatment. Our design strategy integrated sample pretreatment function into the nanozyme through separation and enrichment, thereby improving the selectivity and sensitivity of nanozyme-based colorimetric biosensing. As a proof-of-concept, glucose was used as the model analyte in this study. A phenylboric acid-modified magnetic nanozyme (Cu/Fe3O4@BA) was rationally designed and synthesized. Selectivity was enhanced by boronate-affinity specific adsorption and the elimination of interference after magnetic separation. In addition, magnetic solid-phase extraction enrichment was used to improve the sensitivity. A recovery rate of more than 80% was reached when the enrichment factor was 50. The synthesized magnetic Cu/Fe3O4@BA was recyclable at least five times. The proposed method exhibited excellent selectivity and sensitivity, simple operation, and recyclability, providing a novel and practical strategy for designing multifunctional nanozymes for biosensing.


Biosensing Techniques , Colorimetry , Copper , Glucose , Biosensing Techniques/methods , Colorimetry/methods , Copper/chemistry , Glucose/analysis , Glucose/isolation & purification , Glucose/chemistry , Nanostructures/chemistry , Limit of Detection , Solid Phase Extraction/methods , Boronic Acids/chemistry , Adsorption
8.
J Chromatogr A ; 1722: 464874, 2024 May 10.
Article En | MEDLINE | ID: mdl-38598893

Hydroxypropyl methyl cellulose (HPMC) is a type of cellulose derivative with properties that render it useful in e.g. food, cosmetics, and pharmaceutical industry. The substitution degree and composition of the ß-glucose subunits of HPMC affect its physical and functional properties, but HPMC characterization is challenging due to its high structural heterogeneity, including many isomers. In this study, comprehensive two-dimensional liquid chromatography-mass spectrometry was used to examine substituted glucose monomers originating from complete acid hydrolysis of HPMC. Resolution between the different monomers was achieved using a C18 and cyano column in the first and second LC dimension, respectively. The data analysis process was structured to obtain fingerprints of the monomers of interest. The results revealed that isomers of the respective monomers could be selectively separated based on the position of substituents. The examination of two industrial HPMC products revealed differences in overall monomer composition. While both products contained monomers with a similar degree of substitution, they exhibited distinct regioselectivity.


Hypromellose Derivatives , Mass Spectrometry , Hydrolysis , Hypromellose Derivatives/chemistry , Mass Spectrometry/methods , Chromatography, Liquid/methods , Isomerism , Glucose/chemistry , Glucose/analysis , Liquid Chromatography-Mass Spectrometry
9.
Biosens Bioelectron ; 256: 116280, 2024 Jul 15.
Article En | MEDLINE | ID: mdl-38603840

Monitoring biomarkers in human interstitial fluids (ISF) using microneedle sensors has been extensively studied. However, most of the previous studies were limited to simple in vitro demonstrations and lacked system integration and analytical performance. Here we report a miniaturized, high-precision, fully integrated wearable electrochemical microneedle sensing device that works with a customized smartphone application to wirelessly and in real-time monitor glucose in human ISF. A microneedle array fabrication method is proposed which enables multiple individually addressable, regionally separated sensing electrodes on a single microneedle system. As a demonstration, a glucose sensor and a differential sensor are integrated in a single sensing patch. The differential sensing electrodes can eliminate common-mode interference signals, thus significantly improving the detection accuracy. The basic mechanism of microneedle penetration into the skin was analyzed using the finite element method (FEM). By optimizing the structure of the microneedle, the puncture efficiency was improved while the puncture force was reduced. The electrochemical properties, biocompatibility, and system stability of the microneedle sensing device were characterized before human application. The test results were closely correlated with the gold standard (blood). The platform can be used not only for glucose detection, but also for various ISF biomarkers, and it expands the potential of microneedle technology in wearable sensing.


Biosensing Techniques , Equipment Design , Extracellular Fluid , Glucose , Needles , Wearable Electronic Devices , Humans , Extracellular Fluid/chemistry , Biosensing Techniques/instrumentation , Glucose/analysis , Smartphone , Blood Glucose Self-Monitoring/instrumentation , Continuous Glucose Monitoring
10.
ACS Appl Mater Interfaces ; 16(15): 19605-19614, 2024 Apr 17.
Article En | MEDLINE | ID: mdl-38568178

Wearable sweat sensors have received considerable attention due to their great potential for noninvasive continuous monitoring of an individual's health status applications. However, the low secretion rate and fast evaporation of sweat pose challenges in collecting sweat from sedentary individuals for noninvasive analysis of body physiology. Here, we demonstrate wearable textiles for continuous monitoring of sweat at rest using the combination of a heating element and a microfluidic channel to increase localized skin sweat secretion rates and combat sweat evaporation, enabling accurate and stable monitoring of trace amounts of sweat. The Janus sensing yarns with a glucose sensing sensitivity of 36.57 mA cm-2 mM-1 are embroidered into the superhydrophobic heated textile to collect sweat directionally, resulting in improved sweat collection efficiency of up to 96 and 75% retention. The device also maintains a highly durable sensing performance, even in dynamic deformation, recycling, and washing. The microfluidic sensing textile can be further designed into a wireless sensing system that enables sedentary-compatible sweat analysis for the continuous, real-time monitoring of body glucose levels at rest.


Biosensing Techniques , Wearable Electronic Devices , Humans , Sweat/chemistry , Microfluidics , Glucose/analysis , Monitoring, Physiologic , Textiles , Biosensing Techniques/methods
11.
Nat Commun ; 15(1): 2828, 2024 Apr 02.
Article En | MEDLINE | ID: mdl-38565532

Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called 'personalized lag time'. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.


Contact Lenses, Hydrophilic , Diabetes Mellitus , Animals , Humans , Glucose/analysis , Blood Glucose , Tears/chemistry , Diabetes Mellitus/diagnosis
12.
ACS Appl Mater Interfaces ; 16(14): 17219-17231, 2024 Apr 10.
Article En | MEDLINE | ID: mdl-38561895

Herein, we demonstrate the detection of glucose in a noninvasive and nonenzymatic manner by utilizing an extended gate field-effect transistor (EGFET) based on the organic molecule pyrene phosphonic acid (PyP4OH8) incorporated nickel metal-organic framework (NiOM-MOF). The prepared electrode responds selectively to glucose instead of sucrose, fructose, maltose, ascorbic acid, and uric acid in a 1× phosphate buffer saline solution. Also, utilizing the scanning Kelvin probe system, the sensing electrode's work function (Φ) is measured to validate the glucose-sensing mechanism. The sensitivity, detection range, response time, limit of detection, and limit of quantification of the electrode are determined to be 24.5 µA mM-1 cm-2, 20 µM to 10 mM, less than 5 s, 2.73 µM, and 8.27 µM, respectively. Most interestingly, the developed electrode follows the Michaelis-Menten kinetics, and the calculated rate constant (km) 0.07 mM indicates a higher affinity of NiOM-MOF toward glucose. The real-time analysis has revealed that the prepared electrode is sensitive to detect glucose in real human saliva, and it can be an alternative device for the noninvasive detection of glucose. Overall, the outcomes of the EGFET studies demonstrate that the prepared electrodes are well-suited for expeditious detection of glucose levels in saliva.


Diabetes Mellitus , Metal-Organic Frameworks , Humans , Glucose/analysis , Electrodes , Pyrenes
13.
Mikrochim Acta ; 191(5): 267, 2024 04 16.
Article En | MEDLINE | ID: mdl-38627300

A ternary hierarchical hybrid Ni@CoxSy/poly(3,4-ethylenedioxythiophene)-reduced graphene oxide (Ni@CoxSy/PEDOT-rGO) is rationally designed and in situ facilely synthesized as electrocatalyst to construct a binder-free sensing platform for non-enzymatic glucose monitoring through traditional electrodeposition procedure. The as-prepared Ni@CoxSy/PEDOT-rGO presents unique hierarchical structure and multiple valence states as well as strong and robust adhesion between Ni@CoxSy/PEDOT-rGO and GCE. Profiting from the aforementioned merits, the sensing platform constructed under optimal conditions achieved a wide detection range (0.2 µM ~ 2.0 mM) with high sensitivity (1546.32 µA cm-2 mM-1), a rapid response time (5 s), an ultralow detection limit (0.094 µM), superior anti-interference performance, excellent reproducibility and considerable stability. Furthermore, the sensor demonstrates an acceptable accuracy and appreciable recoveries ranging from 90.0 to 102.0% with less than 3.98% RSD in human blood serum samples, indicating the prospect of the sensor for the real samples analysis. It will provide a strategy to rationally design and fabricate ternary hierarchical hybrid as nanozyme for glucose assay.


Blood Glucose , Bridged Bicyclo Compounds, Heterocyclic , Cobalt , Graphite , Nickel , Polymers , Humans , Nickel/chemistry , Blood Glucose/analysis , Reproducibility of Results , Blood Glucose Self-Monitoring , Glucose/analysis
15.
Talanta ; 274: 126010, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38569372

Intracellular glucose detection is crucial due to its pivotal role in metabolism and various physiological processes. Precise glucose monitoring holds significance in diabetes management, metabolic studies, and biotechnological applications. In this study, we developed an innovative and expedient cell-permeable nanoreactor for intracellular glucose based on surface-enhanced Raman scattering (SERS). The nanoreactor was designed with gold nanoparticles (AuNPs), which were engineered with glucose oxide (GOx) and a H2O2-responsive Raman reporter 2-mercaptohydroquinone (2-MHQ). The interaction between 2-MHQ and H2O2 generated by glucose and GOx could simultaneously induce the appearance in the peak at 985 cm-1. Our results showed excellent performance in detecting glucose within the concentration range from 0.1 µM to 10 mM, with a low detection limitation of 14.72 nM. In addition, the glucose distribution in single HeLa cells was evaluated by real time SERS mapping. By combining noble metal particles and natural oxidases, the nanoreactor possesses both Raman activity and enzymatic functionality, thus enables sensitive glucose detection and facilitates imaging at a single cell level, which offers an insightful monitoring of cellular processes.


Glucose , Gold , Metal Nanoparticles , Spectrum Analysis, Raman , Spectrum Analysis, Raman/methods , Humans , HeLa Cells , Gold/chemistry , Metal Nanoparticles/chemistry , Glucose/analysis , Glucose/metabolism , Hydrogen Peroxide/analysis , Hydrogen Peroxide/chemistry , Glucose Oxidase/chemistry , Glucose Oxidase/metabolism
16.
Talanta ; 274: 126042, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38583326

This work emphasizes the utilization of biochar, a renewable material, as an interesting platform for anchoring redox mediators and bioreceptors in the development of economic, environmentally friendly biosensors. In this context, Fe(III) ions were preconcentrated on highly functionalized activated biochar, allowing the stable synthesis of Prussian blue nanostructures with an average size of 58.3 nm. The determination of glucose was carried out by indirectly monitoring the hydrogen peroxide generated through the enzymatic reaction, followed by its subsequent redox reaction with reduced Prussian blue (also known as Prussian white) in a typical electrochemical-chemical mechanism. The EDC/NHS (1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride and N-Hydroxysuccinimide) pair was employed for the stable covalent immobilization of the enzyme on biochar. The biosensor demonstrated good enzyme-substrate affinity, as evidenced by the Michaelis-Menten apparent kinetic constant (4.16 mmol L-1), and analytical performance with a wide linear dynamic response range (0.05-5.0 mmol L-1), low limits of detection (0.94 µmol L-1) and quantification (3.13 µmol L-1). Additionally, reliable repeatability, reproducibility, stability, and selectivity were obtained for the detection of glucose in both real and spiked human saliva and blood serum samples.


Biosensing Techniques , Charcoal , Ferrocyanides , Glucose , Nanostructures , Ferrocyanides/chemistry , Biosensing Techniques/methods , Nanostructures/chemistry , Charcoal/chemistry , Glucose/analysis , Glucose/chemistry , Humans , Enzymes, Immobilized/chemistry , Glucose Oxidase/chemistry , Glucose Oxidase/metabolism , Blood Glucose/analysis , Hydrogen Peroxide/chemistry , Hydrogen Peroxide/analysis , Limit of Detection
17.
Enzyme Microb Technol ; 177: 110428, 2024 Jun.
Article En | MEDLINE | ID: mdl-38547746

The sensing modified electrode was prepared using glucose oxidase immobilized onto vanadium pentoxide xerogel with glass/FTO as support electrode to evaluate the possibility to construct a V2O5/GOx Extended Gate Field Effect Transistor biosensor. Previously, our studies exhibited a sensitivity of V2O5 of 58.1 mV/pH. The use of Nafion® onto V2O5/GOx caused a decrease of mass loss after several cycles compared to the modified electrode without Nafion® during the EQCM and cyclic voltammetrics studies. Electrical characterization of V2O5/GOx demonstrated a tendency to stability after 200 s as a function of applied current. In presence of glucose and in different pH, the current decreased when the glucose concentration increased due to the lower active sites of enzyme. After ten voltammetric cycles, the total charge tends to structural stability. In pH = 5.0, the modified electrode based on V2O5/GOx Extended Gate Field Effect Transistor presented more tendency to sensitivity in different concentration of glucose.


Biosensing Techniques , Electrodes , Enzymes, Immobilized , Glucose Oxidase , Glucose , Vanadium Compounds , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Enzymes, Immobilized/metabolism , Enzymes, Immobilized/chemistry , Glucose Oxidase/metabolism , Glucose Oxidase/chemistry , Glucose/analysis , Vanadium Compounds/chemistry , Transistors, Electronic , Hydrogen-Ion Concentration , Electrochemical Techniques/methods
18.
Lab Chip ; 24(7): 2080-2093, 2024 Mar 26.
Article En | MEDLINE | ID: mdl-38441218

Pancreatic in vitro research is of major importance to advance mechanistic understanding and development of treatment options for diseases such as diabetes mellitus. We present a thermoplastic-based microphysiological system aiming to model the complex microphysiological structure and function of the endocrine pancreas with concurrent real-time read-out capabilities. The specifically tailored platform enables self-guided trapping of single islets at defined locations: ß-cells are assembled to pseudo-islets and injected into the tissue chamber using hydrostatic pressure-driven flow. The pseudo-islets can further be embedded in an ECM-like hydrogel mimicking the native microenvironment of pancreatic islets in vivo. Non-invasive real-time monitoring of the oxygen levels on-chip is realized by the integration of luminescence-based optical sensors to the platform. To monitor insulin secretion kinetics in response to glucose stimulation in a time-resolved manner, an automated cycling of different glucose conditions is implemented. The model's response to glucose stimulation can be monitored via offline analysis of insulin secretion and via specific changes in oxygen consumption due to higher metabolic activity of pseudo-islets at high glucose levels. To demonstrate applicability for drug testing, the effects of antidiabetic medications are assessed and changes in dynamic insulin secretion are observed in line with the respective mechanism of action. Finally, by integrating human pancreatic islet microtissues, we highlight the flexibility of the platform and demonstrate the preservation of long-term functionality of human endocrine pancreatic tissue.


Insulin , Islets of Langerhans , Humans , Insulin/metabolism , Pancreas , Glucose/analysis , Insulin Secretion
19.
ACS Sens ; 9(4): 1866-1876, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38499997

Electromagnetic sensors with flexible antennas as sensing elements have attracted increasing attention in noninvasive continuous glucose monitoring for diabetic patients. The significant radiation performance loss of flexible antennas during mechanical deformation impairs the reliability of glucose monitoring. Here, we present flexible ultrawideband monopole antennas composed of Ti3C2 MXene and cellulose nanofibril (CNF) composite films for continuous glucose monitoring. The flexible MXene/CNF antenna with 20% CNF content can obtain a gain of up to 3.33 dBi and a radiation efficiency of up to 65.40% at a frequency range from 2.3 to 6.0 GHz. Compared with the pure MXene antenna, this antenna offers a comparable radiation performance and a lower performance loss in mechanical bending deformation. Moreover, the MXene/CNF antenna shows a stable response to fetal bovine serum/glucose, with a correlation of >0.9 at the reference glucose levels, and responds sensitively to the variations in blood glucose levels during human trials. The proposed strategy enhancing the mechanical robustness of MXene-based flexible antennas makes metallic two-dimensional nanomaterials more promising in wearable electromagnetic sensors.


Blood Glucose , Cellulose , Titanium , Cellulose/chemistry , Titanium/chemistry , Humans , Blood Glucose/analysis , Nanocomposites/chemistry , Biosensing Techniques/methods , Wearable Electronic Devices , Animals , Nanofibers/chemistry , Glucose/analysis
20.
J Emerg Med ; 66(4): e421-e431, 2024 Apr.
Article En | MEDLINE | ID: mdl-38462394

BACKGROUND: Hyperkalemia is a common electrolyte abnormality that requires urgent treatment. Insulin is an effective treatment for hyperkalemia, but risk factors for developing insulin-induced hypoglycemia exist (e.g., low pretreatment glucose or renal impairment). OBJECTIVE: This study evaluated the impact of a hyperkalemia protocol tailored to glucose concentration and renal function on insulin-induced hypoglycemia. METHODS: This was a retrospective cohort study of emergency department patients with glucose ≤ 100 mg/dL treated with insulin for hyperkalemia. The primary outcome was incidence of hypoglycemia in patients treated prior to (July 1, 2018-June 30, 2019) vs. after (January 1, 2020-December 31, 2020) the protocol update, which individualized insulin and dextrose doses by glucose concentration and renal function. Secondary outcomes included change in potassium and protocol safety. We assessed factors associated with hypoglycemia using multiple logistic regression. RESULTS: We included 202 total patients (preimplementation: 114, postimplementation: 88). Initial insulin dose was lower in the postimplementation group (p < 0.001). We found a nonsignificant reduction in hypoglycemia in the postimplementation group (42.1% vs. 30.7%, p = 0.10). Degree of potassium reduction was similar in patients who received insulin 5 units vs. 10 units (p = 0.72). Higher pretreatment glucose (log odds ratio [OR] -0.05, 95% confidence interval [CI] -0.08 to -0.02) and additional insulin administration (log OR -1.55, 95% CI -3.01 to -0.25) were associated with reduced risk of developing hypoglycemia. CONCLUSION: A hyperkalemia protocol update was not associated with a significant reduction in hypoglycemia, and the incidence of hypoglycemia remained higher than anticipated. Future studies attempting to optimize treatment in this high-risk population are warranted.


Hyperkalemia , Hypoglycemia , Insulin , Humans , Blood Glucose/analysis , Glucose/analysis , Hyperkalemia/drug therapy , Hypoglycemia/drug therapy , Hypoglycemia/chemically induced , Insulin/adverse effects , Kidney , Potassium/blood , Retrospective Studies
...